Categories

Contact Us

Jiangsu Skyray Instrument Co.,Ltd

Address: No.1888 West Zhonghuayuan Rd, Kunshan 215300, Jiangsu, China

Tel: +86-512-57017337

M/P: +8618912663151

E-mail: andy@skyray-instrument.com

Inductively Coupled Plasma

Inductively Coupled Plasma

ICP2060T - Inductively Coupled Plasma Emission Spectrometer ICP 2060T Sequential Inductively Coupled Plasma Emission Spectrometer is designed to measure major, minor and trace elements in various samples with outstanding performance. Features Over 70 elements can be measured Fast analysis, 5-8...

Chat Now

Product Details

ICP2060T - Inductively Coupled Plasma Emission Spectrometer
ICP 2060T Sequential Inductively Coupled Plasma Emission Spectrometer is designed to measure major, minor and trace elements in various samples with outstanding performance.


Inductively Coupled Plasma Features
Over 70 elements can be measured
Fast analysis, 5-8 elements per minute;
Excellent detection limits, at ppb level for most elements
Wide linear dynamic range, reaching 6 orders of magnitude, from ppb to percentage;
Lower gas consumption; Each argon gas cylinder can be used for 8 hours;
Advanced optical design with a fully illuminated holographic grating, with spectral interference correction and high light throughput for improved detection limits
Wide wavelength range
190nm to 500nm with 3600 line grating
190nm to 800nm with 2400 line grating
Computer controlled plasma platform optimizes the viewing position to reduce interferences, improve SNR and minimize
background emissions
Software controlled flow of carrier gas, plasma gas and auxiliary gas provide real time monitor as well as highly stability of flux.
Various types of plasma torches, nebulizer as well as spray chamber are optional.
Choice of auto sampler greatly improves efficiency
Sample waste drained by peristaltic pump ensures stable sample flow rate; Fast pump mode improves productivity
The brand new robust free-running, 27.12 MHz RF generator that delivers unsurpassed performance
Rapid and accurate automatic coupling system ensures the ultimate power transfer efficiency and stability
One-button plasma ignition
By simply click the button "inflame" in software , the plasma can be ignited immediately
The "graph diagnosis" function provides information on instrument status and analysis progress (as figure 3)
Multi-element analysis
After selecting elements and setting measuring parameters, instrument will measure automatically with results directly displayed. (as figure 4)
Enhanced database management
The database contains several thousands of spectral line, where users can choose freely based on application method. (as figure 5)
Strong and User-friendly Software
The professional software provide excellent features and multi access to functions as follow:
Data management, quantitative and qualitative analysis, test parameter setting, one button report generation, background and interference correction, fast calibration mode, instrument status indication, and online self diagnostic.


Specifications of Inductively Coupled Plasma
Size: 1.5m×0.8m×0.8m
Solid State Power
Frequency: 27.12MHz
Frequency stability: <0.05%
Couple method: Auto match
Output power: 800W ~1600W, continuously adjustable with power efficiency more than 65%
Output power stability: ≤0.05%
Induction coil: ID 25mm×3, equipped with three concentric quartz torch tubes of ED 35mm (ID: internal diameter; ED: external diameter)
Spray chamber: Scott double pass spray chamber
Monochromator
Optical type: Czery turner
Focal length: 1000mm
Grating specification: huge holographic grating with 3600L/mil or 2400 L/mil and 80 mm×100mm of ruling area
Resolution: ≤0.015nm (3600 line grating), ≤0.030nm (2400 line grating)
Wavelength range: 195~500 nm for 3600 line grating, 195~800 nm for 2400 line grating.
Electronic Measurement& Control Circuit
Photomultiplier tube specification: R212/R928
Negative high voltage: (-50 ~ -1000) V
Circuit measuring range: (10-12 ~ 10-4) A
Signal acquisition: VF conversion


Technical Specifications of Inductively Coupled Plasma
1)Suitable sample content range:
a. Liquid sample: 0.01ppm~ several thousands ppm
b. Solid or powder sample: 0.001% ~ 70%
2)Repeatability: short-term stability, RSD≤1.5%
3)Long-term stability: RSD≤2%
4)Test speed: 5~8 elements/min
5)Limits of detection (LOD, μg/L) for typical elements: 1ppb~10ppb

Element

La

Ce

Pr

Nd

Sm

Eu

Gd

Tb

λ (nm)

408.672

413.765

414.311

401.225

360.946

381.967

342.247

350.917

LOD

<3.0

<5.0

<5.0

<5.0

< 10.0

< 1.0

<10.0

< 3.0


Element

Dy

Ho

Er

Tm

Yb

Lu

Y

Sc

λ (nm)

353.170

345.600

337.271

313.126

369.419

261.541

371.030

335.373

LOD

<3.0

<3.0

<3.0

<3.0

<1.0

<3.0

<1.0

<1.0


Element

Ta

Nb

Mn

Mg

B

Zn

Co

Si

λ (nm)

226.230

313.340

257.610

279.553

249.773

13.856

228.616

251.611

LOD

<5.0

<5.0

<3.0

<1.0

<10.0

<3.0

<3.0

<10.0


Element

Ni

Cd

Fe

Ca

Mo

V

Be

Ti

λ (nm)

232.003

226.502

239.562

393.366

281.615

310.230

313.041

334.941

LOD

<5.0

<3.0

<3.0

<1.0

<5.0

<5.0

<1.0

<3.0


Element

Cu

Cr

Al

Zr

Ag

Sr

Au

Pt

λ (nm)

324.754

267.716

396.152

343.823

328.068

407.771

242.795

265.945

LOD

<3.0

<5.0

<5.0

<5.0

<3.0

<1.0

<5.0

<5.0


Element

Pd

Ir

Rh

Ru

Ba

λ (nm)

340.458

224.268

343.489

240.272

455.403

LOD

<5.0

<10.0

<10.0

<5.0

<1.0


Element

As

Sb

Bi

Hg

Pb

Ga

Se

λ (nm)

228.812

206.833

223.061

253.652

220.353

294.364

203.985

LOD

≤15

≤15

≤10

≤15

≤15

≤10

≤10


Element

Sn

Te

Ta

Th

Tl

Re

Ge

λ (nm)

242.949

214.281

226.230

283.730

276.787

227.525

209.426

LOD

≤20

≤10

≤5.0

≤10

≤30

≤5

≤15


Element

Os

W

Se

Li

Na

K

λ (nm)

225.585

207.911

203.985

670.784

588.995

766.490

LOD

≤1

≤10

≤30

≤3

≤20

≤60


Application fields of Inductively Coupled Plasma
Rare earth metal
Silicon materials, magnetic materials processing industry
Metallurgical industry: analysis of impurity elements influencing the quality of metal materials
Water quality control:
Geology, Mineral
Petrochemical: measurements of more than 30 elements in crude oil
Pharmacy, hygiene, agriculture, environmental protection, commodities and food industry